The study on effect of waste water temperature on performance of heat pump water heater WTW

Authors

  • Nguyen Van Thai HCMC University of Technology and Education, Vietnam
  • Le Minh Nhut HCMC University of Technology and Education, Vietnam

Corressponding author's email:

thaivng81@gmail.com

Keywords:

thermal efficiency, heat pump, hot water, water chiller system, waste heat

Abstract

This paper presentss effect of waste water temperature on the performance (COP) of WTW (Water to Water) heat pump. The heat pump uses the waste water which is cooling water of air conditioning chiller system as the heat source. . The heat pump system is designed and installed at thermal workshop in Ho Chi Minh City University of Technology and Education. The electrical power of heat pump is 750W, the capacity of storage tank is 160 liters and the required temperature of hot water is 50 oC. Effect of waste water temperature on the COP of the heat pump has been studied both theoretically and experimentally. To evaluate the effect of temperature of the cooling water  from the condenser of the water chiller system on performance (COP) of the heat pump, experiments are performed on different days. The experimental results show that when the cooling water temperature of condenser increases from 33 oC to 37 oC, the COP of hot water heat pump system also increases from 5,7 to 6,7.

Downloads: 0

Download data is not yet available.

References

R.J. Moffat, “Describing the uncertainness in experimental results,” Experimental Thermal and Fluid Science, vol. 1, 1988, pp. 3-17.

Yaxiu Gu and Huqiu Deng, “ The Feasibility Analysis of Wastewater source heat pumps using the uban Wastewater heat”, Research Journal and Applied Science, Engineering and Technology, 4 (18), 2012.

Chen, Wei, Lianga, Shiqiang, et al., Investigation on the thermal performance and optimization of a heatpump water heater assisted by shower waste water. Elsevier, Energy and Buildings 64, 172–181, 2013.

Nguyễn Đức Lợi. Bơm nhiệt. NXB Giáo dục Việt Nam, 2014.

Nguyễn Đức Lợi. Hướng dẫn thiết kế hệ thống lạnh. NXB Khoa học và kỹ thuật, Hà Nội 2005.

Nguyễn Nguyên An. Nghiên cứu chế tạo bơm nhiệt đun nước nóng gia dụng. Tạp chí Năng Lượng Nhiệt, 20-NLN, 109, 1/2013.

Published

27-10-2017

How to Cite

[1]
Nguyễn Văn Thái and Lê Minh Nhựt, “The study on effect of waste water temperature on performance of heat pump water heater WTW”, JTE, vol. 12, no. 4, pp. 65–70, Oct. 2017.

Issue

Section

Research Article

Categories