A study to evaluate the effects of geometrical parameters and flow parameters on the exergy efficiency of tube-in-tube helical heat exchanger by CFD simulation
Corressponding author's email:
luannt@hcmute.edu.vnDOI:
https://doi.org/10.54644/jte.63.2021.71Keywords:
double-pipe heat exchanger, tube-in-tube helical heat exchanger, CFD simulation, exergy efficiency, response surface methodAbstract
The paper presents research on the influence of geometrical and operating parameters on the exergy efficiency of tube-in-tube helical heat exchanger by using numerical simulation (CFD). The analytical solution for the mathematical model involving energy, the effectiveness and the exergy efficiency of a tube-in-tube helical heat exchanger is obtained using an EES (Engineering Equation Solver) program. The results of the study show that, the exergy efficiency increase with increasing the Reynolds number of hot water (Reh), decreasing the Reynolds number of cold water (Rec), increasing coil diameter (Dc), decreasing the coil pitch. In the scope of the survey with Reynolds numbers of hot and cold water (Reh and Rec) from 9000 to 27000 and 10000 to 30000, respectively; coil diameter (Dc) from 60 mm to 120 mm the coil pitch (hc) from 20 mm to 30 mm, then the exergy efficiency of tube-in-tube helical heat exchanger obtained maximum of he = 6,607% corresponding to Reh = 27000, Rec = 10000, Dc =90 mm (Dc/d = 6), hc=25 mm (hc-d = 10 mm).
Downloads: 0
References
Hang, L,, et al,, Compound heat transfer enhancement for shell side of double-pipe heat exchanger by helical fins and vortex generators, Heat and Mass Transfer, 48(7), p,1113-1124, 2012. DOI: https://doi.org/10.1007/s00231-011-0959-5
Sheikholeslami, M,, M, Gorji-Bandpy, and D,D, Ganji, Experimental study on turbulent flow and heat transfer in an air to water heat exchanger using perforated circular-ring, Experimental, Thermal and Fluid Science,70, p,185-195, 2016. DOI: https://doi.org/10.1016/j.expthermflusci.2015.09.002
Braga, C, and F, Saboya, Turbulent heat transfer, pressure drop and fin efficiency in annular regions with continuous longitudinal rectangular fins, Experimental thermal and fluid science, 20(2), p,55-65, 1999. DOI: https://doi.org/10.1016/S0894-1777(99)00026-6
Yang, R, and F,P, Chiang, An experimental heat transfer study for periodically varying-curvature curved-pipe, International journal of heat and mass transfer, 45(15), p,3199-3204, 2002. DOI: https://doi.org/10.1016/S0017-9310(02)00023-6
Dizaji, H,S,, S, Jafarmadar, and F, Mobadersani, Experimental studies on heat transfer and pressure drop characteristics for new arrangements of corrugated tubes in a double pipe heat exchanger, International Journal of Thermal Sciences, 96, p,211-220, 2015. DOI: https://doi.org/10.1016/j.ijthermalsci.2015.05.009
Prabhanjan, D,, G, Raghavan, and T, Rennie, Comparison of heat transfer rates between a straight tube heat exchanger and a helically coiled heat exchanger, International communications in heat and mass transfer, 29(2), p,185-191, 2002. DOI: https://doi.org/10.1016/S0735-1933(02)00309-3
Yang, G,, Z, Dong, and M, Ebadian, Laminar forced convection in a helicoidal pipe with Finite pitch, International Journal of Heat and Mass Transfer, 38(5), p,853-862, 1995. DOI: https://doi.org/10.1016/0017-9310(94)00199-6
Rennie, T,J, and V,G, Raghavan, Experimental studies of a double-pipe helical heat exchanger, Experimental Thermal and Fluid Science, 29(8), p,919-924, 2005. DOI: https://doi.org/10.1016/j.expthermflusci.2005.02.001
Mashoofi, N,, et al,, Fabrication method and thermal-frictional behavior of a tube-in-tube helically coiled heat exchanger which contains turbulator, Applied Thermal Engineering, 111, p,1008-1015, 2017. DOI: https://doi.org/10.1016/j.applthermaleng.2016.09.163
Fouda, A,, et al,, Thermal performance modeling of turbulent flow in multi tube in tube helically coiled heat exchangers, International Journal of Mechanical Sciences, 135, p, 621-638, 2018. DOI: https://doi.org/10.1016/j.ijmecsci.2017.12.015
Kumar, V,, et al,, Pressure drop and heat transfer study in tube-in-tube helical heat exchanger, Chemical Engineering Science, 61(13), p,4403-4416, 2006. DOI: https://doi.org/10.1016/j.ces.2006.01.039
Ma, H, et al,, Experimental study on heat pipe assisted heat exchanger used for industrial waste heat recovery, Applied energy, 169: p, 177-186, 2016. DOI: https://doi.org/10.1016/j.apenergy.2016.02.012
A. Durmus, Heat exchanger and exergy loss in a concentric heat exchanger with snail entrance, Int. Commun. Heat Mass Transfer 29 (3), 303–312, 2002. DOI: https://doi.org/10.1016/S0735-1933(02)00320-2
Hu, Q. G., Zhang, M., Mujumdar, A. S., Xiao, G. N., & Sun, J. C.Drying of edamames by hot air and vacuum microwave combination. Journal of Food Engineering, 77(4), 2006. DOI: https://doi.org/10.1016/j.jfoodeng.2005.08.025